BR-S-02: Standard-rated line without seller tax identifier
Understand BR-S-02, review an example and inspect your invoice XML locally. Check the underlying invoice values before applying a correction.
Last updated: 14 November 2026
- No invoice uploads. The studio processes XML in your browser.
- A resolved check is not full invoice compliance.
What this check means
An invoice with a standard-rated line needs the seller VAT identifier, the seller tax registration identifier or the VAT identifier of the seller tax representative.
Example
A line with category S and 19 % on an invoice whose seller has neither a VAT identifier nor a tax number fails.
How to investigate and repair
Add the seller VAT identifier or tax number. If the supply is not standard rated, correct the VAT category instead of adding an identifier that does not exist.
Open E-invoice Studio, import the original XML or the hybrid PDF and choose Inspect invoice. The check shows the path of the affected element. Correct the value in the software that created the invoice or in the XML editor, then inspect again. Keep the original for your records.
Validation coverage
The studio implements a bounded subset of checks for mapped UBL and CII fields. It is not a complete XSD or Schematron validator. The empty-element rule is applied only to UBL. Signed XML cannot be repaired, and unsupported precision or ambiguous amounts prevent affected arithmetic checks.
Validate the complete document against the exact invoice profile and national requirements before sending it. The studio does not transmit through Peppol.
Tools and sources
Frequently asked questions
Can the studio automatically fix BR-S-02?
No. It reports the affected element and explains the rule. The correct value depends on your records, so you enter it yourself; nothing is deleted or invented automatically.
Does passing this rule mean my invoice is compliant?
No. One arithmetic or structural check cannot verify all required fields, tax treatment, code lists, country rules, PDF/XML agreement or delivery requirements. Full profile validation remains necessary.